American Type Sewage Lifting Devices

American Type units run on 110V / 60Hz with 3450 RPM motor speed, matching the supply conditions of North America and other 60Hz markets. Same collection tank concept, different electrical platform.

Voltage
110V
Frequency
60Hz
Motor speed
3450 RPM
Protection
IP54 – IP55
02Models

8 models in this line

Open any model for the full parameter table, packing data and installation conditions.

03Comparison

Compare published ratings

Values are the catalog figures. Highlighted cells mark the highest published figure in each row.

ParameterWL300BWL450BWL450DWL600BWL600DWL600FWL750BWL900B
Power300 W450 W450 W600 W600 W600 W750 W900 W
Max flow85 L/min115 L/min115 L/min130 L/min130 L/min130 L/min150 L/min170 L/min
Max head6 m8 m8 m9 m9 m9 m11 m12 m
ProtectionIP54IP55IP55IP55IP55IP55IP55IP55
Tank volumeN/AN/AN/AN/AN/AN/AN/AN/A
QuoteQuoteQuoteQuoteQuoteQuoteQuoteQuote
04Structure

Shared construction points

Described as structure, not as a claim of exclusivity.

01

60Hz electrical platform

Motor winding and capacitor configuration are built for 110V / 60Hz supply; parts are not interchangeable with the 50Hz European platform.

02

Cutting impeller for sanitary waste

Designed for toilet, basin and shower discharge where solids need to be reduced before entering a small-bore discharge line.

03

Collection tank with level control

Start and stop levels are set by the factory float control; the catalog values are listed in the parameter table of each model.

05FAQ

Selection questions for this line

How do I choose between European Type and American Type?
By the supply on site. European Type units are built for 220–240V / 50Hz at 2850 RPM; American Type units are built for 110V / 60Hz at 3450 RPM. The platforms are not interchangeable.
Which model suits a single basement bathroom?
A compact unit in the 450W to 600W range normally covers one bathroom group. Confirm the measured lift and discharge route first, because line losses reduce the usable head.
When should I use a DMJ station instead of a compact unit?
When the discharge volume of the building exceeds what a compact tank can buffer, or when the project needs a buried collection tank. The DMJ range runs from 25L to 460L.